0.018-4.36mm Polyesterimide Enameled Round Copper Wire Class180(H)

    Shape type: enameled round copper wire
    Dimension: 0.018-4.36mm
    Thermal Class: 180℃
    Conductor: Copper
    Insulation: Polyesterimide

    1. Scope

    This specification covers polyesterimide enameled round copper wire, class 180 to be used in winding and wiring of transformer, motor, generator and so on. (Hereinafter referred to as wire)

    2. Polyesterimide enameled round copper wire: class 180

    3.Conductor and Insulating Film

    3.1 Conductor
    The conductor shall be transformed into annealed copper wire.

    3.2 Insulating Film
    Baking Polyesterimide insulating varnish shall make the insulating film of the wire Class180 on the conductor uniformly and perfectly.

    4. Characteristics

    The characteristics of wire shall comply with table 2, when tested by 5.0.

    Item Characteristics Test Method
    Appearance No flaws.
    Smooth surface and uniform color.
    Not Sticky
    5.1
    Dimensions To comply with IEC requirements. 5.2
    Flexibility Film free from cracks such as to expose the conduct. 5.3
    Adherence Film free from cracks such as to expose the conduct. 5.4
    Broken-down voltage 1700 V(Min) 5.5
    Resistance to solvent No bubble or blister in film 5.6
    Heat shock Film free from cracks such as to expose the conduct 5.7
    Conductor resistance To comply with IEC requirements 5.8
    Elongation 20%(Min) 5.9

    5. Test methods

    5.1 Appearance
    The appearance shall be examined, as wound on bobbin, for existence of flaw and stain; by naked eye to determine its appearance.
    5.2 Dimensions. The dimensions shall be measured by using of a micrometer.
    5.3 Flexibility: The springiness at room temperature test
    5.4 Adherence The adherence test
    5.5 Broken-down voltage The broken-down voltage test
    5.6 Resistance to Solvent The resistance to solvent test
    5.7 Heat Shock. The heat shock test, the thermostatic box kept in advance at 240±5℃ Min.
    5.8 Conductor Resistance The electrical resistance test
    5.9 Elongation. The elongation test

    6. Inspection.

    The inspection shall be carried out using the test methods 5, on the items specified from 3, 4. If the purchaser and the supplies have an agreement, some items can be omitted.
    (1)Appearance
    (2)Dimensions
    (3)Flexibility
    (4)Adherence
    (5)Broken-down voltage
    (6)Resistance to Solvent
    (7)Heat shock
    (8)Electrical Resistance
    (9)Elongation

    7. Packing

    7.1 Packing requirement. The wire shall be wound uniformly and compactly on the spool, without tangle.
    7.2 Packing size

    Spool Type MEASUREMENT
    d1 d2 D1 D2 H1 H2
    PT-30 22.2 110 24.7 130 24.5 28.5
    PT-60 269 150 296 178 350 400
    Spool Type MEASUREMENT
    d1 d2 D1 D2 H1 H2
    PT-90
    PCZ-315
    300 180 315 200 425 500
    PT-200
    PCZ-400
    375 225 400 250 530 630
    PT-270 435 225 460 280 528 628

    8.Designation

    The wire shall be designated by class and conductor dimension or by symbol and conductor dimensions. Example Enameled Round copper wire, temperature Class 180℃, 0.15mm

    9. Marking

    The spool and container shall be marked at a specified place with the following items: (1)Designation; (2 Dimensions; (3)Manufacturing Lot number;(4)Net weight; (5)Manufacturer.

    10. Attention, storage method in handling, and attention in period and abandonment

    1) Attention in handling
    *Please note use in the place where the ignition source by the fire, static electricity, and the impact spark, etc. is caused enough.
    *Please avoid contact with the medicines such as a strong acid, strong alkali, and organic solvents. *Please wear protective glasses at the coil winding.
    *The harmful gas is generated from the insulation film when removing the insulation film by heat or solder. Please use the exhaust equipment, and do not inhale directly.
    *Please follow the instruction concerning handling, when you use the medicines for removing. *Please do not roll bobbin to generate loosening and the tangle of the wire.
    * There is a possibility of causing a minute crack on the insulation film when touching it to moisture, water, the solvent, and the medicine, while suffering stress to the insulation film. Therefore, we recommend heat-treating it after the coil is built or before the varnish is processed.
    *Please note handling when you move the wire, and do not treat the product by the hand that attaches the moist hand and the hand cream.
    2 )Attention in keeping
    *Please store it in a room, avoid it being under the high temperature and humidity environment or exposed directly to the sunshine.
    *Please mind the pile height.

    3)Storage:
    Storage temperature: 5~35℃
    Relative humidity: 85% or less (Do not generate the dewy on the surface of the wire.)

    4) Attention in Recycle
    Please recycle if it is possible because copper is main material in this product. When recycling is impossible, please process as industrial waste.

    Get A Quote

    Freely send the inquiry of enameled wire to LP Industry